Rights and Permissions

Background The purpose of this study was to compare photorefraction using Plusoptix vision screening with that of standard cycloplegic refraction, to detect variability between different observers. Patients and methods In this prospective comparative study, the right eyes of 203 children were included. Refraction was performed for each child using Plusoptix photorefraction screener by two separate observers. Under the effect of cyclopentolate eye drops, retinoscopic cyclorefraction was performed for those under 4 years of age, and cyclorefraction using autorefractometer was performed for those 4 years or older. Results In this study, 203 patients with 203 eyes were included, 110 (54.2%) of them were boys and 93 (45.8%) were girls. The mean age of the children was 6.61±4.49 years (range from 4 months to 16 years), and 74 (36.5%) of them were less than 4 years of age and 129 (63.5%) at least 4 years of age. There was no significant difference between the two observers, as regards mean spherical equivalent (+0.52±1.54 D with range of −3.8 to +5.38 for observer 1 and 0.540±1.63 D with range of −3.8 to +4.8 for observer 2). In all age groups, there was no significant difference between photorefraction results and the final objective refraction, as regards mean spherical equivalent (0.540±1.62 and 0.549±1.62 D, respectively). Myopic shift was noted with higher refractive errors. Conclusion Compared with standard cycloplegic refraction, photorefraction using Plusoptix screener was found to be a valuable and reproducible method in spite of the tendency to myopic shift at higher refractive errors in children.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed70    
    Printed8    
    Emailed0    
    PDF Downloaded17    
    Comments [Add]    

Recommend this journal