• Users Online: 426
  • Home
  • Print this page
  • Email this page
Home Current issue Ahead of print Search About us Editorial board Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2019  |  Volume : 112  |  Issue : 3  |  Page : 104-107

Trabeculectomy with Ologen matrix implant versus trabeculectomy with mitomycin-C in primary open-angle glaucoma


Ophthalmology Department, Faculty of Medicine, Mansoura University, Mansoura, Egypt

Correspondence Address:
MD Tarek Mohsen
Ophthalmology Department, Faculty of Medicine, Mansoura University, Mansoura, 35516
Egypt
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ejos.ejos_35_19

Rights and Permissions

Background The purpose of this study was to compare the efficacy and the safety of trabeculectomy augmented with Ologen matrix implant versus mitomycin-C (MMC) in cases with primary open-angle glaucoma (POAG). Patients and methods This retrospective comparative study included patients with POAG who presented to the Ophthalmic Center, Mansoura University, from January 2016 to January 2017. Patients were allocated into two groups: group A patients underwent trabeculectomy with Ologen implant and group B included patients who underwent trabeculectomy with MMC. The primary outcome was the change in the intraocular pressure (IOP), with the recorded complications considered as the secondary outcomes. All the patients were followed up for at least 1 year postoperatively. Results A total of 30 eyes of 17 patients were included in the study. There was no statistically significant difference between the two groups in the baseline demographic or clinical data. The IOP dropped from 43.07±6.23 to 16.03±4.2 mmHg at the twelfth month in group A (P<0.0001) and from 41.41±5.11 to 15.13±2.75 mmHg in group B (P<0.0001). The mean IOP was continuously higher in group A than in group B along the follow-up points, but the difference was statistically insignificant (P>0.05). Hypotony with thin blebs was statistically higher in the MMC group. Conclusion Trabeculectomy augmented with Ologen implant seems to provide the same efficacy as MMC, with fewer complications in cases with POAG.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed84    
    Printed8    
    Emailed0    
    PDF Downloaded24    
    Comments [Add]    

Recommend this journal